The test software used in our products is a perfect match for Windows' CDCS learning material, which enables you to enjoy the best learning style on your computer. Our CDCS certification guide also use the latest science and technology to meet the new requirements of authoritative research material network learning. Unlike the traditional way of learning, the great benefit of our CDCS learning material is that users can flexibly adjust their learning plans. We hope that our new design of CDCS test questions will make the user's learning more interesting and colorful.
EXIN CDCS Exam Syllabus Topics:
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
>> Download CDCS Free Dumps <<
Pass Guaranteed 2024 EXIN CDCS: EXIN EPI Certified Data Centre Specialist –High Hit-Rate Download Free Dumps
Our CDCS training quiz is provided by PDF, Software/PC, and App/Online, which allows you to choose a suitable way to study anytime and anywhere. The PDF versions of CDCS study materials can be printed into a paper file, more convenient to read and take notes. You can also try the simulated exam environment with CDCS software on PC. Anyway, you can practice the key knowledge repeatedly with our CDCS test prep, and at the same time, you can consolidate your weaknesses more specifically.
EXIN EPI Certified Data Centre Specialist Sample Questions (Q49-Q54):
NEW QUESTION # 49
Three data centers are benchmarked on facilities energy efficiency.
Data center A has achieved a PUE of 2.45.
Data center B has achieved a PUE of 1.20.
Data center C has achieved a PUE of 1.90.
Which of the data centers is operating at the highest facility efficiency?
- A. PUE does not indicate efficiency
- B. Data center A
- C. Data center B
- D. Data center C
Answer: B
Explanation:
A Power Usage Effectiveness (PUE) of 1.20 (achieved by Data Center B) indicates the highest facility efficiency among the three data centers. A lower PUE value signifies better energy efficiency, as it means that a greater proportion of the total energy consumed is used directly for IT equipment rather than for cooling, lighting, or other facility needs.
Detailed Explanation:
PUE is calculated as the ratio of total facility energy to IT equipment energy. A PUE close to 1.0 suggests that almost all the energy is dedicated to computing processes, with minimal overhead. With PUE values of 2.45, 1.20, and 1.90, Data Center B (1.20) operates most efficiently by devoting a higher percentage of its total energy to IT equipment.
EPI Data Center Specialist References:
The EPI curriculum emphasizes PUE as a key metric for data center efficiency, with lower values representing better performance. Achieving a PUE near 1.0 aligns with industry best practices for energy-efficient data center design and operation.
NEW QUESTION # 50
A 5kW (power consumption) server keeps crashing with the message 'temperature too high'.
The intake temperature is measured at 25 °C/77 °F and a relative humidity (RH) level of 50%.
The exhaust temperature is 29 °C/84 °F and 45% RH.
The raised floor is providing an adequate amount of CFM/CMH at a reasonable velocity.
The pressure under the raised floor is approximately 25 Pa/0.1 inch H₂O.
Analyze the situation and indicate what the most likely cause is for this server to crash.
- A. No cause could be determined as the CFM/CMH of the air conditioning equipment is not stated
- B. The exhaust temperature is exceeding the ASHRAE recommended values
- C. Dust inside the server causing issues with convection-based heat transfer
- D. The raised floor pressure is too low and/or the raised floor tile % opening is not adequate
Answer: C
Explanation:
The server's repeated overheating despite adequate intake and exhaust temperatures suggests that dust buildup inside the server may be impeding heat transfer. Dust accumulation can obstruct airflow within the server, insulate components, and disrupt the convection-based cooling systems that regulate internal temperatures, leading to overheating and potential hardware failures.
Detailed Explanation:
While the intake and exhaust temperatures appear within acceptable ranges, internal dust can reduce airflow and impede cooling efficiency, causing internal components to overheat despite seemingly normal ambient conditions. Regular cleaning and maintenance are critical for preventing dust-related issues, especially in high-powered equipment like a 5kW server.
EPI Data Center Specialist References:
EPI emphasizes regular maintenance to prevent dust buildup in data center equipment. Dust can significantly impact cooling efficiency and lead to overheating, which underlines the importance of routine cleaning for optimal server performance.
NEW QUESTION # 51
The air intake of the mission-critical server at the top of the rack is measuring 25 °C/77 °F.
Is this acceptable?
- A. Yes, this is allowed according to the standards and guidelines
- B. Depends on the ANSI/TIA-942 Rating the data center needs to comply with
- C. As long as it does not exceed the average server room temperature of 38 °C/100 °F
- D. No, the temperature needs to be 20 °C/68 °F
Answer: A
Explanation:
An air intake temperature of 25 °C (77 °F) at the top of the rack is acceptable according to data center standards and guidelines, such as those from ASHRAE. This temperature falls within the recommended range for inlet temperatures, which is typically between 18°C (64°F) and 27°C (81°F).
Detailed Explanation:
ASHRAE standards provide guidelines on acceptable temperature ranges for air intake in data centers to balance cooling efficiency and equipment safety. A temperature of 25°C is within the recommended operational range, allowing data centers to optimize energy efficiency while maintaining safe conditions for IT equipment.
EPI Data Center Specialist References:
EPI guidelines align with ASHRAE recommendations for server intake temperatures, confirming that 25°C is within acceptable limits for most mission-critical equipment. This ensures the data center maintains an efficient and reliable environment.
NEW QUESTION # 52
What is the main disadvantage of using a ToR (Top of Rack) design?
- A. There will be more switches to manage.
- B. A single ToR (Top of Rack) switch is more expensive than an EoR (End of Row) switch.
- C. You need a separate rack to install all your ToR (Top of Rack) switches.
- D. A ToR (Top of Rack) switch has only optical interfaces.
Answer: A
Explanation:
A Top of Rack (ToR) design typically requires more switches because each rack has its own switch to manage network connections, as opposed to End of Row (EoR) or centralized designs, which consolidate switches. While ToR designs improve cabling efficiency and reduce latency, they also increase the number of switches, thus raising management complexity and potentially increasing capital and operational costs.
Detailed Explanation:
In a ToR setup, each rack's individual switch allows for quick access and streamlined cabling within the rack. However, this setup means more devices to configure, monitor, and maintain, which can increase administrative overhead and network management complexity.
EPI Data Center Specialist References:
EPI documentation notes that ToR designs can improve performance but also lead to increased management needs due to the higher switch count, making them less ideal in environments where simplified network management is prioritized.
NEW QUESTION # 53
You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F. Calculate the approximate CFM required to cool the equipment in the rack.
- A. Approximately 160 CFM
- B. Approximately 1,500 CFM
- C. Approximately 500 CFM
- D. Approximately 1,000 CFM
Answer: D
Explanation:
To calculate the cooling airflow requirement for ICT equipment, you can use the formula:
CFM=Power (kW)×3160ΔT(°F)text{CFM} = frac{text{Power (kW)} times 3160}{Delta T (text{°F})}CFM=ΔT(°F)Power (kW)×3160 For equipment consuming 6 kW with a Delta-T of 20°F:
CFM=6×316020=948≈1,000 CFMtext{CFM} = frac{6 times 3160}{20} = 948 approx 1,000 , text{CFM}CFM=206×3160=948≈1,000CFM Detailed Explanation:
This formula provides an estimate of the cubic feet per minute (CFM) of air required to cool the equipment based on its power consumption and the temperature difference (Delta-T) between intake and exhaust. The Delta-T represents the cooling effectiveness of the airflow.
EPI Data Center Specialist References:
EPI recommends using this calculation for determining airflow requirements in data centers, ensuring that cooling systems are adequately sized to maintain equipment within safe temperature limits.
NEW QUESTION # 54
......
2Pass4sure is one of the leading platforms that has been helping EXIN EPI Certified Data Centre Specialist (CDCS) exam candidates for many years. Over this long time period we have helped EXIN EPI Certified Data Centre Specialist (CDCS) exam candidates in their preparation. They got help from 2Pass4sure EXIN CDCS Practice Questions and easily got success in the final EXIN CDCS certification exam. You can also trust EXIN CDCS exam dumps and start preparation with complete peace of mind and satisfaction.
CDCS Valid Exam Bootcamp: https://www.2pass4sure.com/EPI-Data-Centre/CDCS-actual-exam-braindumps.html
- CDCS Exam Tests ???? CDCS Free Exam ➡️ CDCS New Study Questions ???? Immediately open [ www.pass4test.com ] and search for ( CDCS ) to obtain a free download ????Visual CDCS Cert Exam
- Valid CDCS Real Test ???? New CDCS Test Duration ???? Online CDCS Bootcamps ???? Search for ( CDCS ) and easily obtain a free download on ▷ www.pdfvce.com ◁ ????CDCS Trusted Exam Resource
- Download CDCS Free Dumps - 100% Pass Quiz EXIN First-grade CDCS Valid Exam Bootcamp ???? Copy URL { www.examcollectionpass.com } open and search for “ CDCS ” to download for free ????CDCS Exam Tests
- Exam CDCS Pattern ???? Reliable CDCS Test Tutorial ???? CDCS Free Exam ???? Simply search for ⏩ CDCS ⏪ for free download on ( www.pdfvce.com ) ????CDCS New Test Materials
- Practical Download CDCS Free Dumps - Leader in Qualification Exams - Hot CDCS: EXIN EPI Certified Data Centre Specialist ⛺ Search for 《 CDCS 》 and download exam materials for free through { www.examcollectionpass.com } ⛷CDCS Exam Tests
- 2024 Download CDCS Free Dumps | Efficient EXIN CDCS Valid Exam Bootcamp: EXIN EPI Certified Data Centre Specialist ???? Open website 「 www.pdfvce.com 」 and search for ➡ CDCS ️⬅️ for free download ????CDCS Trusted Exam Resource
- CDCS latest dumps - free EXIN CDCS dumps torrent - CDCS free braindumps ❓ Search for { CDCS } and download it for free on ▷ www.examcollectionpass.com ◁ website ????CDCS Exam Dumps
- Correct Download CDCS Free Dumps - Marvelous CDCS Valid Exam Bootcamp - Precise EXIN EXIN EPI Certified Data Centre Specialist ???? Simply search for ⇛ CDCS ⇚ for free download on [ www.pdfvce.com ] ????Valid CDCS Mock Exam
- Download CDCS Free Dumps - 100% Pass Quiz EXIN First-grade CDCS Valid Exam Bootcamp ???? Download ⏩ CDCS ⏪ for free by simply searching on ➽ www.passcollection.com ???? ????Visual CDCS Cert Exam
- Download CDCS Free Dumps - 100% Pass Quiz EXIN First-grade CDCS Valid Exam Bootcamp ◀ Immediately open ⏩ www.pdfvce.com ⏪ and search for ▶ CDCS ◀ to obtain a free download ????CDCS Valid Braindumps Ppt
- Correct Download CDCS Free Dumps - Marvelous CDCS Valid Exam Bootcamp - Precise EXIN EXIN EPI Certified Data Centre Specialist ???? Search for ▶ CDCS ◀ and download exam materials for free through ☀ www.real4dumps.com ️☀️ ????CDCS Exam Dumps
- CDCS Exam Questions
BONUS!!! Download part of 2Pass4sure CDCS dumps for free: https://drive.google.com/open?id=1mi-4oMkZD2poCw1Oyoe5vz17nw0OSPhY